Hager Controls Bp 10140 Manual Top |verified|
If you’ve inherited a Hager BP 10140 or recently picked up this reliable digital time switch (often identified alongside the model), you might find the interface a bit daunting at first. Whether you're managing commercial lighting or industrial loads, getting the manual settings right is key to efficiency. Understanding the
Use the manual top switch to confirm the relay is not physically stuck or damaged.
If the dial does not turn, the motor may be faulty or not receiving power.
Carefully align the front housing with the baseplate and snap it into place. Restore the mains power supply to the heating system. Operating and Programming Instructions
The circuit is continuously closed, bypassing the timer. hager controls bp 10140 manual top
If your device is a standard gray or white digital timer featuring an LCD screen and four tactile buttons, it is likely part of the .
At the end of its lifecycle, this electronic component must not be disposed of with standard household waste. It should be recycled at a designated collection point for electrical and electronic equipment (WEEE compliance).
[ TOP TERMINALS ] 1 2 3 4 5 [_] [_] [_] [_] [_] ===================== | [ LCD SCREEN ] | | | | (A) (B) (+) (-) | <-- Programming Buttons =====================
: Single-channel output for controlling one specific circuit or load. If you’ve inherited a Hager BP 10140 or
: Potential-free contacts (often terminals 1 and 2) that act as a switch for the load.
Wiring the Coil (A1/A2): Connect the control circuit to terminals A1 and A2. This is the low-power circuit that triggers the switching mechanism.
The is a specific digital time switch model (often associated with the EG103 series). It is designed for precise automated control of electrical loads like lighting, heating, or pumps. Key Features of the BP 10140 / EG103
Proper installation is critical for the longevity of the device and the safety of the electrical system. If the dial does not turn, the motor
To locate the "top" official documentation, follow these technical guidelines:
: The device typically comes with the date and time pre-set. If a reset is needed, the device can be programmed even when not connected to a power supply. Manual Overrides :
Secure the backplate to the wall or a standard flush-mounting box using the provided screws. Pull the system wires through the central cable entry zone. 3. Wiring Connections
Connect two units in series (+V of unit 1 to -V of unit 2) to achieve 48V DC. Do not exceed the insulation rating of the unit (typically 60V DC max).