The Leica TC 407 total station remains a reliable workhorse for surveyors, engineers, and construction professionals worldwide. Known for its precision optics and robust build, this instrument still delivers exceptional field performance.
The specific driver you need depends entirely on the cable you use to connect the total station to your PC. 1. Official Leica GEV189/GEV267 USB Cables
While officially supported up to Windows XP/7, these drivers can often be run on Windows 10 and 11 by manually updating the " " or "USB Serial Converter" entry in the Device Manager. 2. Required Data Transfer Software
If you cannot transfer data or get connection errors, try these proven fixes. Fix "Code 10: Device Cannot Start" Error
: Because the TC 407 uses a legacy RS232 serial connection, modern USB-to-serial cables (like the GEV267) require specific drivers to translate data for Windows operating systems. Hardware and Software Synergy LEICA TC 407 driver
If data transfers but results in gibberish text file formatting:
Technical Report: Leica TC407 Connectivity and Drivers The (part of the TPS400 series) is a legacy total station that requires specific hardware and software configurations for data transfer to modern computers. Because the TC407 primarily uses a serial interface, "drivers" typically refer to the USB-to-Serial cable drivers rather than the instrument itself. 1. Essential Driver and Hardware Components
Open your Leica software and set the COM Port to match the one assigned in Device Manager (e.g., COM3).
Leica Geosystem file format – GSI file | Jaison's Blog - WordPress.com The Leica TC 407 total station remains a
The Leica TC407 does not have a native USB port. It communicates via a proprietary 5-pin or 8-pin Lemo serial port. To connect it to a modern PC, you must use a specific cable assembly:
This is the most common issue on Windows 10/11 with older Prolific cables. Open and right-click the faulty port.
Often provides updated Leica-specific virtual COM port drivers.
and select the folder where you extracted the Leica USB drivers. Once installed, the device should appear as a Serial USB Converter with an assigned COM port (e.g., COM3). 4. Data Transfer Setup Required Data Transfer Software If you cannot transfer
Drivers only enable the connection; you need software to actually transfer data:
19200 (Default, though 9600 is safer for longer cables) Flow Control: XON/XOFF or Hardware How to Check Settings on the TC407: Turn on the instrument. Navigate to Menu > Settings > Communication .
Run the downloaded driver installer .exe file as an Administrator.
If your software says the COM port is unavailable or timed out:
: Detailed driver lists and software patches (like Leica Instrument Tools ) can often be found on specialized dealer support pages like SCCS Surveying Knowledge Base .
The Leica TC407 is a discontinued model, superseded by the Leica FlexLine series (TS02, TS06, TS09). Official driver support for the TC407 may be phased out as Windows evolves. For continued use, stockpile , create a backup of your current drivers , and test the hardware on a newer Windows 11 machine to check for any latent compatibility issues.